Position Sensor
On this page
A position sensor records where one point is relative to another point, in the axes of a chosen frame.
Parameters
Units are shown in SI (m, kg, s, N, rad). MOMDYN does not enforce units, so any consistent set works, but angles are always in radians.
| Name | Type | Default | Units | Description |
|---|---|---|---|---|
point_key | str | 'origin' | — | The point whose position is sensed. |
ref_point_key | str | 'origin' | — | The point that the sensed position is measured relative to. |
ref_frame_key | str | 'inertial' | — | The frame that the sensed position is expressed in. |
Equations
The sensed quantity is the position vector from the reference point Q to the point P, resolved in the axes of frame F:
Sign conventions & notes
The sensor adds three time series (x, y and z) to the simulation output.
A real counterpart is a linear variable differential transformer (LVDT). The simulated sensor has none of its range or contact limits.